![]() ![]() What happens when you press the "TEST" button on a circuit breaker in an electric panel?.When were GFCI receptacle outlets first required?.Where are GFCI receptacle outlets required?.What is the difference between GFCI and AFCI circuit breakers?.What electrical hazards does a Ground Fault Circuit Interrupter (GFCI) NOT protect against?.What does "listed and labeled" mean for an electrical component?.How do I identify a combination AFCI (CAFCI) circuit breaker?.Does a washing machine receptacle outlet require GFCI protection?.When did arc fault circuit interrupter (AFCI) breakers first become required?.When was GFCI-protection for kitchen dishwasher receptacle outlet first required?.What is the code requirement for GFCI protection for receptacles near a wet bar sink?.Does a septic pump or sump pump require a GFCI-receptacle?.Here’s links to a collection of our other blog posts about AFCI and GFCI RECEPTACLES AND CIRCUIT BREAKERS: This is especially common in a garage.Īlso, see our blog posts Are Ground Fault Circuit Interrupters (GFCIs) really necessary and worth the trouble? and What is the difference between what trips a GFCI (ground fault) receptacle and a circuit breaker? The GFCI-receptacle may be concealed by a multi-plug outlet adapter mounted over it.These receptacles are supposed to have stickers on them to advise of GFCI-protection but no equipment ground. Many of the receptacles in non-wet areas, such as living room and bedrooms, may be protected by a nearby GFCI-receptacle where you would not expect to find one. If the they were upgraded to three-slot, putting a GFCI-receptacle at the head of each circuit or in the panel, is a way to comply with safety requirements without actually retrofitting a ground connection for the grould slot in every receptacle. Most homes built before 1960 had two-slot ungrounded receptacles. GFCI-protection is accepted by the National Electrical Code (NEC) as an alternative to grounding for a three-slot receptacle.Receptacles in the dining room, breakfast room, and pantry are often in the same circuit as a kitchen counter GFCI. We once found a GFCI-receptacle on the wall of a laundry that protected receptacles in an adjacent half-bathroom and garage. Scan nearby “wet” rooms that would require GFCI-protection for the receptacles.Sometimes a GFCI-receptacle under a bar-height countertop on the other side of the kitchen counter from an open kitchen protects counter receptacles nearby in the kitchen.When this is done, the new GFCI-receptacle often does not actually trip (the reset button will be popped out if it’s tripped), but the one in the garage or panel does trip. Someone unwittingly changed out a regular receptacle for a GFCI, to add shock protection that was already there. If the receptacle has GFCI test and reset buttons, but the reset button doesn’t work, it is may be because the receptacle was originally protected by a GFCI-breaker in the main panel or a GFCI-receptacle in the garage.The GFCI for a spa tub can be at a GFCI-receptacle in the bathroom, in the compartment with the spa pump, a GFCI-breaker in the electric panel, or a dead front GFCI nearby in the bathroom, in an adjacent closet, or on the wall next to the electric panel.The GFCI-device can be a breaker in an electric panel, a receptacle with push-buttons, or a dead front GFCI like the one shown below, which looks like a GFCI-receptacle without any place to plug in a power cord.Ī few more pointers if your are still searching: ![]() The switch must be pushed all the way to OFF, and then back to ON to reset.Īs we get into the 2000s and newer homes, it gets more complicated because of the requirements for GFCI-protection in more wet locations, such as the kitchen, laundry, utility rooms, and wet bars. Some GFCI-breakers trip half-way between ON and OFF, so it may not be obvious by the switch position at first glance that it is tripped. The spa tub sometimes had its own GFCI-breaker in the panel, and the newer ones have tiny reset buttons compared to the old ones. They were expensive back then, and one GFCI-receptacle placed at the head of a circuit protected everything downstream on a circuit that ran all around the house. Or it may be located in one of the bathrooms, especially if it is a mobile home. Late 1970s to mid-80s homes usually have a GFCI-breaker in the electric panel, like the one shown below, and it protects all the bathroom and exterior receptacles.įor homes built in the late 1980s thru the 90s, there is typically one GFCI-receptacle in the garage that covers the bathrooms, exterior, spa tub, and other garage receptacles. Let’s start with the era in which the house was built. ![]()
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |